1000 series Online Gas Detector can be used for gas concentration detection and leakage alarm in various environments. It has intelligent sensor detection technology, overall flameproof (d) structure, and fixed installation. Real-time display of various technical indicators and gas concentration values.
Compatible with various control alarms, PLC, DCS and other control systems. Realize on-site alarm warning, 4-20mA/RS485 standard signal output, relay switch output.
Features
- The sensor has good anti-interference performance and a service life of up to 3-5 years;
- It adopts advanced microprocessor technology, with fast response speed, high measurement accuracy, good stability and repeatability;
- The detection site has on-site sound and light alarm function. Instant alarm when gas concentration exceeds the standard. It is a safety guarantee for dangerous on-site operations;
- On-site large-screen LCD display with backlight. Intuitive display of gas concentration/type/unit/working status, etc.;
- Independent gas chamber, easy replacement of sensors. No on-site calibration is required for replacement. Automatic identification of key sensor parameters;
- Full range temperature digital automatic tracking compensation to ensure measurement accuracy;
- Ultra-low power consumption of semiconductor nanotechnology 32 Micro-position measuring instrument;
- Full software automatic calibration. The sensor has up to 6 target point calibration functions. Ensure the accuracy and linearity of the measurement, and have data recovery function;
- With overvoltage protection, lightning protection, short circuit protection, reverse connection protection, anti-static interference, anti-magnetic field interference and other functions;
- With automatic recovery function to prevent external reasons, human reasons, natural disasters and other damage to the instrument;
- Simple and practical, with temperature compensation function;
- Automatic protection function against high concentration gas shock.
Specifications
Types | With display and alarm; With display but without alarm; Made entirely of stainless steel; Wireless signal transmission; |
Detection range | 0-100%LEL, 0-1%/10%/30%/100%VOL, 0-5/10/100/1000/10000ppm, mg/m³ (depending on the sensor principle) |
Working voltage | DC24V±10% |
Sampling accuracy | ±2%FS |
Repeatability | ±2%FS |
Working temperature | -30~70℃ |
Storage temperature | -40~70℃ |
Working current | ≤50mA |
Installation method | Fixed, wall-mounted, diffused, etc. installation |
Receiving device | User computer, control alarm, PLC, DCS, DDC, etc. |
Service life | 3~5 years |
Output signal | ①4-20mA signal: standard 12-bit precision 4-20mA output chip, transmission distance 1Km ②RS485 signal: standard MODBUS RTU protocol, transmission distance 1Km ③ Voltage signal: 0.4-2V, 0-5V, 0-10V output, optional (voltage output and current output, choose one) ④ Switch signal: 1 set of passive contact relays, capacity 220VAC 3A/24VDC 3A ⑤ GPRS, 4G, WIFI, LORA, ZigBee and other wireless signals, optional |
Baud rate | 9600 |
Detection principle | Catalytic combustion/electrochemistry/infrared NDIR/semiconductor/thermal conductivity/PID photoionization (depending on the measured medium) |
Response time | <10S |
Working humidity | 0-100% RH (no condensation) |
Long-term drift | ≤±2% FS/year |
Warm-up time | 30S |
Working air pressure | 80KPa~120KPa |
Warranty period | 2 years |
Shell material | Aluminum alloy |
Explosion-proof form | The probe transmitter and sensor are both explosion-proof. |
Explosion-proof grade | ExdIICT6 |
Protection grade | IP66 waterproof splash and short-term rain, long-term rain requires optional rain cover or housing without display |
Alarm method | On-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc. |
Alarm setting | Standard configuration of two-level alarm, optional three-level alarm; alarm mode can be set: conventional high and low alarm, interval control alarm |
Electrical interface | Default M20X1.5 internal thread, optional 3/4NPT, 1/2NP |
Connecting cable | ①4~20mA selects three-core shielded cable, RS485 selects four-core, when the distance exceeds 1000 meters (with one detector), the single wire diameter is ≥1.5mm, and the shielding layer is connected to the ground. ②Wireless transmission: Built-in LORA, Zigbeg module, short-distance wireless transmission; external GPRS/4G module, remote data transmission to the cloud platform, can view historical records on the computer and mobile phone, without distance restrictions (optional) |

Online Gas Detector Detectable Gases and Measuring Ranges
Detection gas | Range | Maximum allowable error | Minimum reading | Response time T90 |
Combustible gas (EX) | 0-100%LEL | <±3%(F.S) | 0.1%LEL | ≤10 seconds |
Combustible gas (EX) | 0-100%Vol | <±3%(F.S) | 0.1%Vol | ≤10 seconds |
Methane (CH4) | 0-100%LEL | <±3%(F.S) | 0.1%LEL | ≤10 seconds |
Methane (CH4) | 0-100%Vol | <±3%(F.S) | 0.1%Vol | ≤10 seconds |
Oxygen (O2) | 0-30%Vol | <±3%(F.S) | 0.01%Vol | ≤10 seconds |
Oxygen (O2) | 0-100%Vol | <±3%(F.S) | 0.01%Vol | ≤10 seconds |
Oxygen (O2) | 0-5000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Nitrogen (N2) | 0-100%Vol | <±3%(F.S) | 0.01%Vol | ≤10 seconds |
Carbon monoxide (CO) | 0-100ppm | <±3%(F.S) | 0.1ppm | ≤25 seconds |
Carbon monoxide (CO) | 0-1000ppm | <±3%(F.S) | 0.1ppm | ≤25 seconds |
Carbon monoxide (CO) | 0-2000ppm | <±3%(F.S) | 0.1ppm | ≤25 seconds |
Carbon monoxide (CO) | 0-20000ppm | <±3%(F.S) | 1ppm | ≤25 seconds |
Carbon monoxide (CO) | 0-100000ppm | <±3%(F.S) | 1ppm | ≤20 seconds |
Carbon dioxide (CO2) | 0-500ppm | <±3%(F.S) | 1ppm | ≤20 seconds |
Carbon dioxide (CO2) | 0-2000ppm | <±3%(F.S) | 1ppm | ≤20 seconds |
Carbon dioxide (CO2) | 0-5000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Carbon dioxide (CO2) | 0-50000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Carbon dioxide (CO2) | 0-20%Vol | <±3%(F.S) | 0.01%Vol | ≤30 seconds |
Carbon dioxide (CO2) | 0-100%Vol | <±3%(F.S) | 0.01%Vol | ≤30 seconds |
Carbon dioxide (CO2) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Formaldehyde (CH2O) | 0-10ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Formaldehyde (CH2O) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤45 seconds |
Formaldehyde (CH2O) | 0-1000ppm | <±3%(F.S) | 1ppm | ≤20 seconds |
Ozone (O3) | 0-1ppm | <±3%(F.S) | 0.001ppm | ≤20 seconds |
Ozone (O3) | 0-5ppm | <±3%(F.S) | 0.001ppm | ≤20 seconds |
Ozone (O3) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ozone (O3) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ozone (O3) | 0-2000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Ozone (O3) | 0-30000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Ozone (O3) | 0-20mg/L | <±3%(F.S) | 0.01mg/L | ≤30 seconds |
Ozone water (O3) | 0-20mg/L | <±3%(F.S) | 0.01mg/L | ≤30 seconds |
Hydrogen sulfide (H2S) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Hydrogen sulfide (H2S) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Hydrogen sulfide (H2S) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Hydrogen sulfide (H2S) | 0-2000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Hydrogen sulfide (H2S) | 0-10000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Sulfur dioxide (SO2) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤45 seconds |
Sulfur dioxide (SO2) | 0-20ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Sulfur dioxide (SO2) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Sulfur dioxide (SO2) | 0-500ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Sulfur dioxide (SO2) | 0-2000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Sulfur dioxide (SO2) | 0-10000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Nitrogen monoxide (NO) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Nitrogen monoxide (NO) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Nitrogen monoxide (NO) | 0-2000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Nitrogen dioxide (NO2) | 0-5000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Nitrogen dioxide (NO2) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Nitrogen dioxide (NO2) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Nitrogen dioxide (NO2) | 0-1000ppm | <±3%(F.S) | 0.1ppm | ≤25 seconds |
Nitrogen dioxide (NO2) | 0-5000ppm | <±3%(F.S) | 1ppm | ≤25 seconds |
Nitrogen dioxide (NO2) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Nitrogen oxides (NOX) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Nitrogen oxides (NOX) | 0-2000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Nitrogen oxides (NOX) | 0-5000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Chlorine (CL2) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Chlorine (CL2) | 0-20ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Chlorine (CL2) | 0-200ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Chlorine (CL2) | 0-2000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Ammonia (NH3) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ammonia (NH3) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ammonia (NH3) | 0-1000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Ammonia (NH3) | 0-5000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Ammonia (NH3) | 0-100%LEL | <±3%(F.S) | 0.1%LEL | ≤30 seconds |
Hydrogen (H2) | 0-100%LEL | <±3%(F.S) | 0.1%LEL | ≤30 seconds |
Hydrogen (H2) | 0-1000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Hydrogen (H2) | 0-20000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Hydrogen (H2) | 0-40000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Hydrogen (H2) | 0-100%Vol | <±3%(F.S) | 0.01%Vol | ≤30 seconds |
Helium (He) | 0-100%Vol | <±3%(F.S) | 0.01%Vol | ≤10 seconds |
Argon (Ar) | 0-100%Vol | <±3%(F.S) | 0.01%Vol | ≤10 seconds |
Xenon (Xe) | 0-100%Vol | <±3%(F.S) | 0.01%Vol | ≤30 seconds |
Hydrogen cyanide (HCN) | 0-30ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Hydrogen cyanide (HCN) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Hydrogen chloride (HCL) | 0-20ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Hydrogen chloride (HCL) | 0-200ppm | <±3%(F.S) | 0.1ppm | ≤20 seconds |
Phosphine (PH3) | 0-5ppm | <±3%(F.S) | 0.001ppm | ≤20 seconds |
Phosphine (PH3) | 0-25ppm | <±3%(F.S) | 0.01ppm | ≤20 seconds |
Phosphine (PH3) | 0-2000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Chlorine dioxide (CLO2) | 0-1ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Chlorine dioxide (CLO2) | 0-10ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Chlorine dioxide (CLO2) | 0-200ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ethylene oxide (ETO) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ethylene oxide (ETO) | 0-1000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Ethylene oxide (ETO) | 0-100%LEL | <±3%(F.S) | 1%LEL | ≤30 seconds |
Phosgene (COCL2) | 0-1ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Phosgene (COCL2) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Silane (SiH4) | 0-1ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Silane (SiH4) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Fluorine (F2) | 0-1ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Fluorine (F2) | 0-10ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Fluorine (F2) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Hydrogen fluoride (HF) | 0-10ppm | <±3%(F.S) | 0.01ppm | ≤20 seconds |
Hydrogen fluoride (HF) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤20 seconds |
Hydrogen bromide (HBr) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Diborane (B2H6) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Arsine (AsH3) | 0-1ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Arsine (AsH3) | 0-10ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Arsine (AsH3) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Germane (GeH4) | 0-2ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Germane (GeH4) | 0-20ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Hydrazine (N2H4) | 0-1ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Hydrazine (N2H4) | 0-300ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Tetrahydrothiophene (THT) | 0-100mg/m3 | <±3%(F.S) | 0.01mg/m3 | ≤30 seconds |
Bromine (Br2) | 0-10ppm | <±3%(F.S) | 0.001ppm | ≤30 seconds |
Bromine (Br2) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Bromine (Br2) | 0-2000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Acetylene (C2H2) | 0-100%LEL | <±3%(F.S) | 0.1%LEL | ≤30 seconds |
Acetylene (C2H2) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Acetylene (C2H2) | 0-1000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Ethylene (C2H4) | 0-100%LEL | <±3%(F.S) | 0.1%LEL | ≤30 seconds |
Ethylene (C2H4) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ethylene (C2H4) | 0-2000ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Acetaldehyde (C2H4O) | 0-10ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ethanol (C2H6O) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Ethanol (C2H6O) | 0-2000ppm | <±3%(F.S) | 1ppm | ≤60 seconds |
Methanol (CH6O) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Methanol (CH6O) | 0-2000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Carbon disulfide (CS2) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Carbon disulfide (CS2) | 0-5000ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Acrylonitrile (C3H3N) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Acrylonitrile (C3H3N) | 0-2000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Methylamine (CH5N) | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
I2 | 0-50ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Styrene (C8H8) | 0-200ppm | <±3%(F.S) | 0.1ppm | ≤30 seconds |
Styrene (C8H8) | 0-5000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Vinyl chloride (C2H3CL) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Trichloroethylene (C2HCL3) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Tetrachloroethylene (C2CL4) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Laughing gas (N2O) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Nitrogen trifluoride (NF3) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Hydrogen peroxide (H2O2) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Sulfuryl fluoride (SO2F2) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Sulfuryl fluoride (SO2F2) | 0-30000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Sulfuryl fluoride (SO2F2) | 0-200g/m3 | <±3%(F.S) | 0.1g/m3 | ≤30 seconds |
Sulfuryl fluoride (SO2F2) | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
Sulfuryl fluoride (SO2F2) | 0-5000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
Sulfuryl fluoride (SO2F2) | 0-10000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |
C6H6 | 0-10ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
C6H6 | 0-100ppm | <±3%(F.S) | 0.01ppm | ≤30 seconds |
C6H6 | 0-2000ppm | <±3%(F.S) | 1ppm | ≤30 seconds |

Online Gas Detector is suitable for real-time and accurate detection of gas concentration and leakage in various environments. Fixed installation, suitable for 24-hour continuous online monitoring in various hazardous places. For example: electrolyte gas detection, NMP gas detection, hexafluoroacetone detection, hydrochloric acid gas detection, methane detection, etc.
Sino-Inst’s Online Gas Detector is widely used in petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, tunnels and other occasions that require fixed installation and online detection of gas concentration.
If you need to perform gas concentration, gas leakage and other detections, please feel free to contact our sales engineer!