The Compact Ambient Air Quality Monitoring System(AQMS) is a next-generation online multi-parameter air quality monitoring system. It primarily measures PM2.5, PM10, CO, SO2, NO2, O3, TVOC, various environmental pollutants, particulate matter, and meteorological parameters.
monitoring data.

This system is widely used for urban air quality monitoring and industrial air emission pollution monitoring.

Features

Specifications

Monitoring Factors and Measurement Range
Sulfur Dioxide (SO2)Measuring range0~500ppb;
2000ppb
Detection principleElectrochemistryResolution1ppb
Nitrogen Dioxide (NO2)Measuring range0~500ppb;
2000ppb
Detection principleElectrochemistryResolution1ppb
Ozone (O3)Measuring range0~500ppb;
2000ppb
Detection principleElectrochemistryResolution1ppb
Carbon Monoxide (CO)Measuring range0~5ppm;
20ppm;
50ppm;
Detection principleElectrochemistryResolution0.01ppm
TVOCMeasuring range0~5ppm;
20ppm;
50ppm;
Detection principlePID photoionization (optional)Resolution0.01ppm
PM2.5Measuring range0~500μg/m³Detection principleLight scattering
PM10Measuring range0~2000μg/m³Detection principleLight scattering
Weather MonitoringWind speed, wind direction, temperature, humidity, atmospheric pressure, ambient noise, and light (optional)
Combination Method1-10 gas factors
Particulate matter (PM2.5, PM10)
6-8 meteorological factors (optional)
Total number of monitored factors not exceeding 20 (optional combination)
Sampling methodPump-type
Mounting methodWall-mounted, floor-standing
Indication errorDepends on the specific detection factor; refer to the factory label for accuracy.
Power supply voltageAC180-250V, 50Hz
Output signalRS485 digital output (Modbus RS485)
2 relay outputs
Signal transmission method①RS-485 digital transmission (Modbus RS485)
②Supports HJ212 protocol, compliant with the “HJ212-2017 Pollutant Online Monitoring (Monitoring) System Data Transmission Standard”
③ Supports TCP/IP transmission over the network: TCP/IP protocol, supports transmission up to 90 meters over a network cable, and long-distance real-time transmission via networking (optional).
④ Supports fiber optic transmission: Up to 20 to 40 kilometers (single-mode multi-core fiber optic cable transmission, requires a fiber optic modem), networking is optional.
⑤ Supports short-distance RTU433 wireless transmission: Transmission distance 0 to 2 kilometers, depending on transmission power and site environment (optional).
⑥ Supports GPRS wireless transmission: Unlimited distance (optional).
CalibrationCalibration supports 2-4 levels of calibration.
Display7-inch color touchscreen display (optional)
Touch operation with push buttons (optional)
Data loggingAutomatic data storage, capable of continuously storing over 20 million sets of data with date and time (optional)
Operating temperature-20°C to +60°C (typical)
Operating humidity0% to 85% RH
Case dimensions350mm x 420mm x 190mm (width x height x depth)
Casing materialSPCC (customizable stainless steel)
IP ratingIP65
Case weight20-30kg
Ambient Air Quality Monitoring System installation

How does AQMS Work?

The ambient air quality monitoring system can be configured with optional measurement modules for gases, particulate matter, and meteorological parameters based on user needs. It is a new, low-cost, intelligent air quality monitoring device.

The AQMS air quality monitoring system consists of four components: a sampling device, analyzers, a calibration device, and a data acquisition system. Gaseous pollutant analyzers include analyzers for SO2, NO, O3, CO, VOCs, laser gas (HCl, HF, NH3), and a NO2 analyzer (CAPS cavity attenuation phase shift spectrometer). Particulate matter analyzers include PM2.5, PM10, and an extinction analyzer (aerosol analyzer).

The system workflow is as follows:

Typical Applications

  • Urban air quality monitoring, short-term and long-term air quality trend analysis and evaluation;
  • Grid-based air quality monitoring by relevant management departments at the provincial, municipal, county (district), and town (village or sub-district office) levels;
  • Air quality monitoring in densely populated areas such as communities, schools, and hospitals;
  • Atmospheric monitoring in chemical plants, petrochemical plants, power plants, landfill incineration plants, sewage treatment plants, storage facilities, and underground facilities;
  • Air quality monitoring in urban roads, airports, ports, railways, tunnels, and construction sites;
  • Air quality monitoring in open areas such as parks, woodlands, and crop research sites;
  • Particulate matter and pollution source emission monitoring;
  • Environmental quality assessment;

More Air and Gas Monitors

The Compact Ambient Air Quality Monitoring System is used for urban air quality monitoring and industrial air pollution monitoring. It measures various air pollutants, particulate matter, and meteorological parameters.

The Sino-Inst Compact Ambient Air Quality Monitoring System supports external communication interfaces and features data storage and export capabilities. It transmits measurement data to a monitoring center in real time via a wireless data acquisition and transmission terminal and allows remote control via a web browser.

If you require configuration of the Ambient Air Quality Monitoring System or have any technical questions, please feel free to contact us!