The insertion type dust monitor is a professional instrument that monitors dust concentration and specific gas components in real time by directly inserting into the pipeline or container.

Using the microcomputer laser principle and electrostatic AC induction principle, it can continuously measure the particle concentration and gas content in the target environment. It is widely used in industrial production monitoring, environmental protection and other aspects.

Features

1. Provide 24/7 uninterrupted monitoring data. Timely detect abnormal changes in concentration. Provide a reliable basis for process control and safety management.

2. Direct contact with the measured medium avoids sampling delay.

3. Adopt plug-in design, no complex sampling pipeline system is required. Installation only requires opening an interface of appropriate size on the pipe or container.

4. The installation and use are exactly the same as the three-wire pressure transmitter. On-site engineering and technical personnel can use it correctly without special training.

5. The 4-20mA current output by the built-in integrated transmitter in the junction box is electrically isolated from the dust sensor probe to achieve safe signal transmission.

6. The sensor body adopts an airtight connector design. Strictly prevent the leakage of the measured gas and the extrusion of the measuring electrode due to pressure. Ensure the safety of the transmitter and staff.

7. Adopt special materials and protective design, which can withstand harsh working conditions such as high temperature, high pressure, high humidity, and corrosive media.

Specifications

DustIncluding: dust, coal powder, flour, dust, smoke, graphite, manganese dioxide, quicklime and other particulate matter
Dust particle size rangeNominal 0.1μM~200μM, it can still be received outside the nominal range but the signal characteristics are a little different.
Operating environment temperature-20℃~60℃ (electronic components)
Operating environment humidityHumidity 90%
Operating environment protectionProtection level: IP66/NEMA4 aluminum alloy shell, suitable for installation in non-corrosive environment, stainless steel probe
Pipeline gas pressure-0.1~1MPa
Pipeline gas flow rate1m/s~30m/s
Pipeline gas temperature0℃~250℃ (260℃-800℃ can be customized)
Pipeline outer diameter0.1m~4m
Probe structureThe standard probe is φ16mm, length 100mm-1000mm, probe material: rare earth amorphous alloy,
Zero drift(Time) Less than 1% of the range per year.
Zero drift(Temperature) Less than 1% of the range within the specified temperature range.
Full scale drift(Time) Less than 1% of the range per year
Full scale drift(Temperature) Less than 1% of the range within the specified temperature range.
Line stabilityAll system components are made of high-stability electronic assemblies.
Noise resistanceAll 50 or 60 Hz audio and harmonics are filtered out before the signal is received
Measurement range0-10mg/50mg/100mg/200mg/1000mg/30g/100g/m3
Transmitter output modeTwo-wire 4-20mA (built-in isolator, explosion-proof and anti-interference)
Transmitter power supply24V (available in the range of 15V to 32V)
Measurement accuracy±5%
Probe length selectionPlease select the probe length according to the formula, that is, D/3 ≤ L ≤ 2D/3 (where: D – pipe inner diameter, L – probe length)

Insertion type dust monitor size

Working Principle

Insertion Type Dust Monitor measures the electrostatic charge induction of dust particles passing through a fixed probe.

The dust particles and the probe induce electrostatic charge, which is amplified by the probe and transmitted to the monitoring control system. The size of the electrostatic charge is proportional to the flow rate of the dust particles.

The high-tech electronic circuit of this system converts this part of the charge into a control signal output. It activates the dust emission alarm and is used to continuously record the total amount or concentration of dust particles.

Under relatively stable combustion conditions (i.e., at the same emission point, the flow rate, temperature, pressure, humidity and smoke particle properties do not change much, less than ±90% of the change), this system can also be used for online monitoring of emission concentration (unit = mg/M3) after direct calibration.

Featured Applications

Insertion Type Dust Monitor is widely used in various industrial applications, including steelmaking, power generation, petroleum, building materials processing, coal mining, cement manufacturing and packaging.

Typical uses include:

1. Industrial production monitoring:

In industrial production such as mining, metallurgy, and power plants, Insertion Type Dust Monitor is used to monitor the dust concentration generated during the production process to ensure production safety and worker health.

In the raw material crushing, raw material grinding, clinker calcination, cement grinding and other links of cement production, dust concentration monitoring is crucial. Insertion Type Dust Monitor is designed for such high dust environments. The measurement range is 0-1000mg/m³, and the accuracy is ±2. It is an ideal choice for safe production in cement plants.

Monitoring of CO concentration in process gases such as blast furnace gas, converter gas, and coke oven gas in iron and steel metallurgy, as well as dust control in processes such as raw material processing, sintering, and coking, all require reliable plug-in detection equipment. Equipped with a high-temperature probe, it can withstand a medium temperature of 800°C.

2. Environmental protection:

Environmental monitoring departments use dust detectors to detect atmospheric dust and investigate pollution sources to assess environmental pollution and take corresponding measures.

3. Public safety:

In terms of municipal smoke monitoring, monitor the smoke content in urban air to provide data support for urban air quality management.

4. Scientific research:

The plug-in dust detector is used in filter material performance tests and other experiments that require on-site testing. It helps scientific researchers obtain accurate dust concentration data.

5. Labor health monitoring:

In the labor department of industrial and mining enterprises, by measuring the dust concentration at the production site, it ensures that the working environment meets health and safety standards and protects workers from dust hazards.

Insertion type dust monitor installation

Choosing the right testing equipment is not only about meeting compliance requirements, but also about taking responsibility for enterprise safety production, employee health and environmental protection.

Sino-Inst is committed to providing customers with the most reliable dust and gas detection solutions. Our products have been successfully used in more than 300 countries and regions around the world. Whether it is a standard product or a special customization, Sino-Inst’s professional team will provide you with the best technical support and service guarantee.